Your ICS Integrator Holds the Plant Schematics. Where Are They Stored?

The FBI and CISA published a fact sheet on the risks of working with third-party industrial control system integrators. The case they cite: 800 files of customer SCADA information exfiltrated from an automation company. The questions they raise are contract questions, not firewall questions.

On 23 September 2026, the FBI and CISA jointly published a fact sheet for critical infrastructure operators about the risks that arise when working with third-party industrial control system integrators. The document describes no new attack and contains no CVE. It describes a contractual relationship.

For Romania, where almost no industrial plant, water treatment station or distribution network is designed and maintained exclusively with in-house staff, the subject is more relevant than it first appears. The integrator is the party that knows the installation in detail — often better than its owner does.

02

The risks the agencies identify

  • Supply chain risks, from unsecured components and procurement practices that carry no security requirements.
  • Data exposure when the integrator stores network designs and device specifications outside the jurisdiction, under different data governance regimes.
  • The integrator's network as a pivot point: an attacker who compromises them reaches customers' operational environments.
  • Loss of operational independence if the integrator becomes unavailable or compromised and the organisation cannot operate or recover without them.
03

The case the agencies cite

The document refers to a 2025 incident in which attackers accessed the network of an industrial automation company and exfiltrated approximately 800 files containing, in the agencies' wording, "customer SCADA information, ICS device details, and other schematics".

It is worth pausing on what that means. No customer installation was compromised. The supplier holding the documentation of those installations was. For an attacker planning an operation against an industrial network, schematics and device inventories are exactly the reconnaissance work they would otherwise have to do themselves, at the risk of being detected.

It is the kind of loss that produces no alert at the customer, appears in none of their logs, and is generally not reported as their incident.

04

What the document recommends, briefly

  • In contracts and service agreements: explicit requirements on where data is stored, how remote access works, change and patch management, changing default credentials, a named list of personnel with access, and the availability of local engineering support.
  • For remote access: monitor all integrator access, use on-demand access approved case by case by an operator, and know where the devices are actually hosted.
  • For documentation and inventory: request a complete inventory of supplied software and hardware, connection documentation, and update procedures.
  • For operational resilience: maintain manual operation capability, keep offline backups of critical software, and hold recovery procedures that do not depend on third-party support.
  • In risk assessment: data autonomy, the impact on process control, and geopolitical considerations when choosing or reassessing an integrator.
05

What this document is and is not

  • It is a joint fact sheet from two US agencies, published on 23 September 2026. It is not a legal obligation, in the United States or the European Union, and it certifies no supplier.
  • It describes no new vulnerability and demands no urgent action. It is material for reviewing contracts and practices, at your own pace.
  • The 2025 incident is cited by the agencies without naming the affected company, and further details are not public in the source consulted.
  • For a European organisation, the document's value is the list of requirements — they are stated concretely enough to be placed in a tender specification.
06

The question few ask when signing

Of the whole list, one deserves to be pulled forward because it is rarely asked and almost never in writing: where are our plant schematics stored, and who, by name, has access to them?

The typical answer — "on our servers, securely" — is not an answer. A usable answer contains a country, a type of system, a list of people, and a commitment to notify you of an incident at the supplier. The difference between the two is the difference between knowing and assuming.

The second question, asked just as rarely: if the integrator disappears tomorrow — bankruptcy, attack, litigation — can we operate the installation and recover it without them? If the answer depends on one particular person at their firm, that is not a supplier relationship but a dependency.

07

The NIS2 connection, without overstating it

For essential and important entities, the directive requires risk-management measures that explicitly include supply chain security and relationships with direct suppliers. A US fact sheet appears nowhere in European legislation and cannot be presented as evidence of compliance. It can, however, serve as a starting point for the clauses you require, and those clauses are exactly the kind of evidence missing from most supplier files.

The practical difference is between writing "the supplier follows good practice" in the file and being able to show the contract stating where the data is stored, who has access, and how quickly they notify you. Awarely Monitor can connect suppliers, operational assets and closure evidence; contract negotiation and the risk decision remain the organisation's own.

Sources and verification